ADC H4TU-C-319 List 1 Line Unit Manuel D’Utilisation

Page de 79
Testing
 
 LTPH-UM-1031-03, Issue 3
48
September 12, 2003
 H4TU-C-319 List 1
Manual Loopback Session 
A manual loopback session allows you to select any one of the HDSL4 loopbacks listed in 
with the exception of SmartJack loopbacks, which can only be issued by inband commands.
Setting the Loopback Time-Out Option (LBTO)
Before initiating a loopback session, verify that the Loopback Time-Out parameter is set to the desired setting. 
1
Use the MODE and SEL pushbuttons as described in 
(The loopback time-out parameter is also user-selectable from the Config Menu, Standard Options screen 
when using a maintenance terminal.)
2
Select the desired setting:
NONE (time-out disabled)
20 minutes
60 minutes
120 minutes 
8 hr
24 hr
Activating Manual Loopback Mode
To initiate a manual loopback session: 
1
Press both the MODE and SEL pushbuttons on the front panel for at least 3 seconds. The following message 
appears on the front-panel display:
MAN LPBK NLO? 
(
XXXX
 indicates loopback choices)
2
Press SEL to activate NLOC. The display changes to 
MAN LPBK NLOC
3
Press MODE to advance to the next available loopback:
NDx? = Doubler 1 or Doubler 2, if H4D is available
NRE? = NREM
CRE? = CREM
With the exception of SmartJack, any of the HDSL4 loopbacks can be executed using the MODE 
and SEL pushbuttons. 
When executing a manual loopback session using the MODE and SEL pushbuttons:
The next loopback option can be displayed by pressing the MODE pushbutton, however, the 
previously activated loopback remains active until the SEL pushbutton is pressed, which 
activates the new loopback. 
If neither pushbutton is pressed for a period of 30 seconds and no loopback is in effect, the 
manual loopback session terminates, and the display returns to normal mode. 
If any loopback is in effect, the 30-second time-out is inhibited. The active loopback and the 
manual loopback sessions continue until the loopback times out in accordance with the 
LBTO setting. 
If there is an active loopback, pressing the MODE and SEL pushbuttons for 3 or more 
seconds terminates any active loopback, ends the manual loopback session, and returns the 
display to normal mode.