ADC H4TU-C-319 List 1 Line Unit Manuel D’Utilisation

Page de 79
LTPH-UM-1031-03, Issue 3
 
Testing
H4TU-C-319 List 1
September 12, 2003
 49
CDx? = Doubler 1 or Doubler 2, if H4D is available
CLO? = CLOC
COL? = Dual loopback at H4TU-C
DxL? = Dual loopback at Doubler 1 or Doubler 2, if available
RUL? = Dual loopback at H4TU-R
4
Press SEL to activate the selected loopback. The previous loopback is terminated.
Once a loopback is selected and activated, the loopback stays active until it times out (based on the LBTO setting). 
When a loopback times out, the display returns to the normal display mode.
You can terminate loopbacks manually and exit the 
MAN LPBK
 mode by simultaneously pressing the MODE and 
SEL pushbuttons for 3 or more seconds. If no loopback is active, the 
MAN LPBK
 mode automatically terminates 
after 30 seconds.
All loopbacks can be initiated by inband commands in the DS1 payload or by a command from the HDSL4 system 
(front-panel pushbuttons or maintenance screen selections). Therefore, whenever a loopback is active, the method 
by which it was activated is indicated in the loopback and status information (Monitor screen) by the annotation 
HG or PL adjacent to the identified loopback. For example, NREM-HG indicates that the loopback was initiated 
by the HDSL4 system.
L
OOPBACK
 T
EST
 P
ROCEDURES
The following sections provide step-by-step test procedures for verifying the integrity of the HDSL4 channels at 
every module location as well as the DS1 channels to the customer and the local DSX-1 interface. 
 summarizes the available loopbacks in the system.
General Troubleshooting Tips
If trouble is encountered on the DSX-1 interface of the H4TU-C, verify that the:
H4TU-C is making a positive connection with its shelf connector. 
H4TU-C internal equalizer is set to the correct distance range pe
. All equalizers should 
be set to the distance from the DSX-1 to the shelf.
The transmit and receive DSX-1 ports have splitting access jacks and miniature, 210-series, bridging jacks as 
shown in 
. Connecting one cable between the two (BRG) jacks and another between the two 
LINE jacks splits the IN and OUT and creates metallic loopbacks towards both the DSX-1 and the H4TU-C-319. 
If separate plugs are inserted into both LINE jacks with the other end disconnected, the BRG jacks can be used to 
send and receive test patterns towards the DSX-1.
SMJK loopback commands are only activated by inband commands.