Configuring and Monitoring through the LCD
 
4-6
Campus-REX RS Interface Card User Manual
Configuring Alarm Thresholds
Alarm thresholds determine the level at which an alarm condition is reached. 
There are two types of HDSL alarm thresholds:
Link ES threshold determines the number of errored seconds that must 
occur to trigger an alarm. This threshold can be set to 17 or 170 errored 
seconds. You can also disable this alarm.
Margin threshold determines the margin, in dB, that triggers an alarm. 
This threshold can be set anywhere between 1 dB and 25 dB, in 1 dB 
increments. You can also disable this alarm.
To set the alarm thresholds:
1
From the 
CURRENT ALARMS
 display, press Next
HDSL LINK 
ALARMS
 displays.
2
Press Enter. The current HDSL alarm status displays.
3
Press Next
HDSL ES THRESHLD
 displays.
4
Press Enter.
5
Press Next to scroll through the settings for the ES threshold until the 
desired setting displays.
6
Press the Enter button to select the desired setting. 
HDSL ES 
THRESHLD
 displays.
7
Press Next
MARGIN THRESHLD
 displays.
8
Press Enter.
9
Press Next to scroll through the settings for the margin threshold until the 
desired setting displays.
10
Press Enter to select the desired setting. 
MARGIN THRESHLD
 displays.