Configuring and Monitoring through the LCD
 
4-8
Campus-REX RS Interface Card User Manual
Viewing Current Alarms
1
From the 
CURRENT ALARMS
 display, press Next until 
HDSL LINK ALARMS
 displays.
2
Press Enter until the current HDSL alarm status displays.
3
Press Next until 
AUTOSYNC:
 displays.
4
If the AutoSync alarm is on or acknowledged, press Enter for more 
information.
Configuring the Alarm
1
From the 
CURRENT ALARMS
 display, press Next until 
HDSL LINK ALARMS
 displays.
2
Press Enter until the current HDSL alarm status displays.
3
Press Next until 
AUTOSYNC CFG ALM
 displays.
4
Press Enter.
5
Press Next to scroll through the settings for the AutoSync alarm until the 
desired setting displays.
6
Press Enter to select the desired setting. 
AUTOSYNC CFG ALM
 
displays.
Local Alarms
Loss of Signal (LOS) alarms can occur on the local unit. This section 
describes how to view and configure this alarm.
Viewing Current Alarms
If the 
CURRENT ALARMS
 display indicates a local alarm, you can determine 
the alarm type:
1
From the 
CURRENT ALARMS
 display, press Next twice. 
LOCAL I/F 
ALARMS CONFIG & STATUS
 displays.
2
Press Enter. The current status of the local alarm displays.