Troubleshooting an ISDN BRI Connection
12-22
PortMaster Configuration Guide
To view the PPP negotiation, enter the following commands:
Command> set console
Command> set debug 0x51
For more information about the interpreting the results of the debug command, refer to 
the PortMaster Troubleshooting Guide
After you verify that the PPP negotiation is correct, enter the following commands to 
turn off the debug utility:
Command> set debug off
Command> reset console
Interpreting ISDN BRI Port Status
Table 12-13 describes how to interpret the output of the show S10 command for ISDN 
BRI ports.
Table 12-13 ISDN BRI Port Status 
Port Status
Modem Status
Description
NO-SERVICE
DCD- CTS- TELCO- NT1-
No SPID is set.
NO-SERVICE
DCD- CTS- TELCO- NT1+
Port has either no cable or no 
circuit connecting it to the 
telephone company.
NO-SERVICE
DCD- CTS+ TELCO+ NT1+
Cable and ISDN circuit are 
functioning, but the SPID is not 
registered.
IDLE
DCD- CTS+ TELCO+ NT1+
SPID is registered and ready to use
ESTABLISHED
DCD- CTS+ TELCO+ NT1+
Port is connecting or providing 
device service, but no carrier is 
sensed.
ESTABLISHED
DCD+ CTS+ TELCO+ NT1+
Port is connected.
ESTABLISHED
DCD+ CTS- TELCO+ NT1+
Port is connected with a V.120 
asynchronous connection, but the 
other end of the connection is 
providing flow control 
information.