Switch Provisioning
Tables
This section provides provisioning information for the following switch 
types in the U.S. and Canada:
AT&T 5ESS
AT&T 5ESS Custom
DMS 100 and National ISDN 1
Siemens EWSD
AT&T 5ESS Switch 
To order ISDN service for an AT&T 5ESS switch, provide the telephone 
company with the information in Table 34. 
Table 34   Ordering ISDN Service for an AT&T 5ESS Switch 
Required Information
Specification
Line type
National ISDN 1 line
Line code
2B1Q (2B+D)
Interface type
S/T interface with NT1 (model 43x) or 
U interface (model 44x) and RJ-45 jack
Maximum terminals (MAXTERM)
1
Maximum B channels (MAXB CHNL)
2
Actual user
Yes
Circuit-switched data
2
Circuit-switched data channel
Any
Terminal type
A-Basic or E-Type (data only) Terminal
Display
No 
Circuit-switched data limit
2
Voice or data
Data
Call appearance
Idle
DN (directory number) must be set as follows:
Parameter
Setting
B1
Circuit-switched data
B2
Circuit-switched data
D
Signaling only
MAXTERM
1
MAXB CHNL
2
ACT USR
Y
CSD
2