Serial I/O:
 Serial Connector Pin Assignments
10002367-02
PmT1 and PmE1 User’s Manual
5-7
Note:
The EIA-232C specification defines a maximum rate of 20,000 bits per second over a typical 50-foot cable 
(2,500 picofarads maximum load capacitance). Higher baud rates are possible, but successful operation 
depends specifically upon the application, cable length, and overall signal quality.
The formula for the synchronous baud rate is:
sync baud rate = (system frequency) ÷ ((clock divider +1) x (Div16))
The clock divider value is stored in bits (12:1) of the BRGC. The Div16 value (1 or 16) is 
selected with bit 0 of the BRGC. 
 lists the clock divider and Div16 values associated 
with typical synchronous baud rates.
Table 5-5:
Synchronous Baud Rates
SERIAL CONNECTOR PIN ASSIGNMENTS
The PmT1 and PmE1 module has a 64-pin connector for the serial I/O interface. The P14 pin 
assignments, including the VME P0 and VME P2 pin numbers specific to Emerson base-
boards are shown in 
Note:
The VME P2 pin numbers are listed for a module installed in expansion site J1x. The VME P0 pin numbers are 
listed for a module installed in expansion site J2x.
Reference “PMC Connector Pin Assignments” Section  for the remaining PMC connectors, 
P11 and P12; and “Front Panel I/O” Section  for the front panel I/O connectors, P1 and P2.
Table 5-6:
P14, P0, P2 Pin Assignments
76800
1
33
75757.6
1.4
System Frequency=40 MHz
Baud 
Rate 
(Kbaud):
Div16 
Value:
Clock Divider + 1:
Actual Frequency:
Frequency Error 
(%):
1544 (T1)
1
26
1538.5
0.4
2048 (E1)
1
20
2000
2.3
P14 Pin:
P0 Pin:
P2 Pin:
Signal:
P14 Pin:
P0 Pin:
P2 Pin:
Signal:
1
E4
C1
Console  RxData
2
3
C4
C2
Console  TxData
4
5
6
7
D5
C4
GND
8
C5
A4
Download  RxData
9
10
A5
A5
Download TxData
11
12
System Frequency=40 MHz 
  (continued)
Baud 
Rate:
Div16 
Value:
Clock Divider + 1:
Actual Frequency: