Emerson PMT1 Manuel D’Utilisation

Page de 128
Setup:
 Troubleshooting
10002367-02
PmT1 and PmE1 User’s Manual
2-7
❐ Be sure the PmT1 and PmE1 circuit board is seated firmly in the baseboard and that the 
baseboard is fully plugged in the chassis.
❐ Be sure the system is not overheating.
❐ Check the cables and connectors to be certain they are secure.
❐ If you are using the PmT1 and PmE1 monitor, run the power-up diagnostics and check 
the results. “Power-up Diagnostic/Test Commands”, Section  describes the power-up 
diagnostics.
❐ Check your power supply for proper DC voltages. If possible, use an oscilloscope to look 
for excessive power supply ripple or noise (over 50 mV
pp
 below 10 MHz).
❐ Check that your terminal is connected to serial port A (SMC1).
❐ The PmT1 and PmE1 monitor uses values stored in on-card NVRAM (I
2
C EEPROM) to 
configure and set the baud rates for its console port. The lack of a prompt might be 
caused by incorrect terminal settings, and incorrect configuration of the NVRAM, or a 
malfunctioning NVRAM. Try holding down the H character during a reset to abort 
autoboot using NVRAM parameters. If the prompt comes up, the NVRAM console 
parameters are probably configured incorrectly. Enter the command nvopen, then the 
command nvdisplay, to check the console configuration. For more information about 
the way NVRAM is used to configure the console port baud rates, refer to Chapter 8.
Technical Support
(800) 327-1251 or (608) 826-8006 (US)
44-131-475-7070 (UK)
Have the following information available when contacting support:
• PmT1 and PmE1 serial number and product identification (see 
• monitor version (see 
 start-up display)
• the baseboard serial number and product identification
• version and part number of the operating system (if applicable) This information is 
labeled on the master media supplied by Emerson or another vendor.
• whether your board has been customized for options such as a higher processor speed 
or additional memory