RAD Data comm ASMi-52 Manuel D’Utilisation

Page de 186
Installation and Operation Manual 
Chapter 6  Troubleshooting and Diagnostics 
ASMi-52 Ver. 2.5 
Troubleshooting 
6-15 
Table 6-4.  ASMi-52 Events 
Terminal Message 
Description 
CRC EVENT LINE A 
CRC errors are detected on line A 
CRC EVENT LINE B 
CRC errors are detected on line B 
SW DOWNLOAD FAIL 
Software download failed 
BUFFER OVERFLOW 
More than 100 entries registered in the log file 
WD RESET FROM GS 
Watchdog error from the SHDSL chipset 
GS OUT OF SYNC ABORT 
SHDSL framer out of sync 
GS LOSS OF CARRIER DETECT 
SHDSL carrier loss  
GS SQ ERROR DETECT 
SHDSL signal quality value is more than 22.7 dB 
GS CRC ERROR DETECT 
More than three SHDSL CRC errors were detected during the last 
second 
REP SEGD ERROR DETECT 
SEGD error from repeater: sync fail on another part of the span 
 TRAINING MODE STACK 
CPE Training state timeout is exceeded (3 min) 
DEVICE PRIMARY CALL FAIL 
The primary number dial attempt has failed 
DEVICE DIAL CALL FAIL 
The dial out call cycle has failed 
6.4 Troubleshooting 
Working with the Port Log File 
ASMi-52 maintains a port alarm buffer, which can store up to 100 alarm messages. 
The port log file specifies alarm or event name, severity (major or minor), status 
(ON or OFF), and time elapsed since the last ASMi-52 reset. 
 
To display the log file: 
•  From the Physical Port Status menu, select Port Log File (Main menu > 
Monitoring > Physical Ports Status > Port Log File). 
The Log File screen appears (see 
Figure 6-15
).