RAD Data comm ASMi-52 Manuel D’Utilisation

Page de 186
Chapter 6  Troubleshooting and Diagnostics 
Installation and Operation Manual 
6-16 Testing 
ASMi-52
 
ASMi-52 Ver. 2.5 
ASMI 52 
Port log file 
Source Name 
Severity 
Status 
Time 
1. Local MNGMNT IS DOWN 
MAJOR 
ON 
0:00:00 
2. Local E1 SYNC LOSS LINE A MAJOR 
ON 
0:00:00 
3. Local E1 SIGNAL LOSS 
MAJOR 
ON 
0:00:00 
4. Local SYNC LOSS LINE A 
MAJOR 
ON 
0:00:00 
5. Local E1 SYNC LOSS 
MAJOR 
OFF 
0:11:48 
6. Local E1 SIGNAL LOSS 
MAJOR 
OFF 
0:11:48 
7. Local SYNC LOSS LINE A 
MAJOR 
OFF 
0:23:22 
8. Local MNGMNT IS DOWN 
MAJOR 
OFF 
0:24:25 
9. Remote LAN NOT CONNECTED  MAJOR 
ON 
0:24:29 
 
ESC-prev. menu; !-main menu; &-exit; @-scroll; ?-help  
1 user(s) 
Figure 6-15.  Port Log File Screen 
 
To clear the log file: 
1.  From the Physical Port Status menu, select Port Clear Log File (Main menu > 
Monitoring > Physical Port Status > Port Clear Log File) to clear the log file. 
A confirmation message is displayed at the bottom of the screen. 
2. Type Y and press <Enter>
All the log file entries are deleted from the log file. 
6.5 Testing ASMi-52 
The user-controlled test functions of ASMi-52 consist of the loopback tests and 
LEDs test. The purpose of these tests is to determine the source of a break in the 
data flow. 
 
•  Both local and remote ASMi-52 units must be configured and synchronized 
properly to allow remote loopback activation. 
•  Only one loopback can be activated at a time, either on the local or remote 
unit.  
 
Note