Installation and Operation Manual  
Quick Start Guide 
ASMi-52 Ver. 2.5 
Configuring ASMi-52 
 
To configure E1 parameters: 
•  From the E1 Port Configuration menu (Main Menu > Configuration > Port 
Configuration > E1 Port Configuration), configure the following E1 
parameters: 
 
Framing mode 
 
Timeslot assignment 
 
•  You can configure timeslot 0 to be looped or transparent: 
 
Looped – timeslot 0 is sent back to the E1 interface, when operating 
opposite remote units with a serial data interface. 
 
Transparent – timeslot 0 is transmitted to the remote modem. 
•  If you operate ASMi-52 with the G732S framing, timeslot 0 is always 
transparent and timeslot 16 is always connected. 
•  When operating a 2-wire ASMi-52 with E1 interface opposite ASMi-52 with 
V.35 interface (not in LS mode), assign at least three timeslots, excluding 
timeslot 0, to carry data. 
•  When operating a 4-wire ASMi-52 with E1 interface opposite ASMi-52 with 
V.35 interface (not in LS mode), assign at least six timeslots, excluding timeslot 
0, to carry data. 
 
Configuring the T1 Interface 
 
To configure the T1 parameters: 
•  From the T1 Port Configuration menu (Main Menu > Configuration > Port 
Configuration > T1 Port Configuration), configure the following T1 parameters: 
 
Framing mode 
 
Line coding 
 
Receive gain 
 
Interface type 
 
Transmit signal mask 
 
Timeslot assignment 
Configuring the 10/100BaseT Interface 
 
To configure 10/100BaseT parameters: 
•  From the LAN Configuration menu (Main Menu > Configuration > System 
Configuration > LAN Configuration), configure the following LAN parameters: 
 
Bridge static table 
 
Aging timeout 
 
LAN rate 
 
Note