ASMi-52 Ver. 2.5 
3.  Type a number corresponding to a subnet mask of the already defined 
network management station, and enter a new value. 
4.  Repeat step 2 and step 3 to define additional management stations. 
5. Press <Esc> to return to the Management menu (see 
Figure 4-1
). 
6.  From the Management menu, select Save to save your changes. 
ASMi-52 
Manager List 
 1. MNG 1  IP      ... (172.17.160.104) 12. MNG 2  MASK    ... (0.0.0.0) 
 2. MNG 2  IP      ... (172.17.160.68)  13. MNG 3  MASK    ... (0.0.0.0) 
 3. MNG 3  IP      ... (0.0.0.0)        14. MNG 4  MASK    ... (0.0.0.0) 
 4. MNG 4  IP      ... (0.0.0.0)        15. MNG 5  MASK    ... (0.0.0.0) 
 5. MNG 5  IP      ... (0.0.0.0)        16. MNG 6  MASK    ... (0.0.0.0) 
 6. MNG 6  IP      ... (0.0.0.0)        17. MNG 7  MASK    ... (0.0.0.0) 
 7. MNG 7  IP      ... (0.0.0.0)        18. MNG 8  MASK    ... (0.0.0.0) 
 8. MNG 8  IP      ... (0.0.0.0)        19. MNG 9  MASK    ... (0.0.0.0) 
 9. MNG 9  IP      ... (0.0.0.0)        20. MNG 10 MASK    ... (0.0.0.0) 
10. MNG 10 IP      ... (0.0.0.0) 
11. MNG 1  MASK    ... (0.0.0.0)  

 
ESC-prev. menu; !-main menu; &-exit; @-scroll 
Figure 4-5.  Manager List Menu 
Controlling the Management Access 
You can enable or disable access to the ASMi-52 management system via Telnet or 
a Web-based application (ConfiguRAD). By disabling Telnet, you prevent 
unauthorized access to the system when security of the ASMi-52 IP address has 
been compromised. When Telnet and Web access are disabled, ASMi-52 can be 
managed via an ASCII terminal only. 
 
To define the management access method: 
1. From the Management Access menu (Main menu > Configuration > System 
Configuration > Management > Management Access),  
(see 
Figure 4-6
), select Telnet Allowed to enable Telnet access, or select Web 
Allowed
 to enable management via a Web browser. 
The access value toggles between Access Allowed and No Access
2. Press <Enter> when a required value is displayed. 
3. Press <Esc> to return to the Management menu (see 
Figure 4-1
). 
4.  From the Management menu, select Save to save your changes.