RAD Data comm ASMi-52 Manuel D’Utilisation

Page de 186
Installation and Operation Manual 
Chapter 4  Configuration 
ASMi-52 Ver. 2.5 
Additional Tasks 
4-45 
ASMi-52 
SW files 
 
 Local 
Remote 
Software active version: 
(2.01E24) 
(2.02000) 
Software active partition: 
(0) 
(0) 
Code size: 
(813110) 
(813161) 
Date: (28-7-4) 
(2-8-4) 
Software backup version: 
(2.01E24) 
(2.01E11) 
Software backup partition: 
(1) 
(1) 
Code size: 
(813110) 
(809233) 
Date: (28-7-24) 
(9-6-4) 
 
Boot version: 
(1.10) 
(1.10) 
Boot mng version: 
(5.34) 
(5.34) 
 
Press any key to continue... 
 
ESC-prev. menu; !-main menu; &-exit 
Figure 4-48.  Software Version Screen 
Switching the Software Versions 
If an active software becomes corrupted, you can switch it with the backup in the 
local ASMi-52 units. 
 
To swap software versions: 
1.  From the File System menu, select the SWAP Local SW Files (Main menu > 
File Utilities > File System > Swap Local SW Files) to swap files in the local 
ASMi-52. 
ASMi-52 displays the following message:  
Request to swap SW files!!! Confirm Y/N 
2. Type Y to confirm the file swap. 
ASMi-52 performs the swap and sends the following string: 
Program Switching 
The active software becomes the backup and vice versa. At this stage, 
ASMi-52 is automatically reset. 
If you try to switch the software versions when only one version is available, 
ASMi-52 responds with the following message: 
Impossible to switch – no other program 
Press any key to continue 
Resetting ASMi-52 
ASMi-52 supports four types of reset: 
•  Reset to the default setting 
•  SHDSL interface reset 
•  SHDSL repeater line reset 
•  Overall reset.