Resetting to Default Settings 
You can reset the local or remote ASMi-52 to its default settings. Resetting to the 
factory default does not affect the master clock setting. In addition, you can reset 
the local ASMi-52 without affecting its management parameters (IP address, mask 
and default gateway). 
 
To reset ASMi-52 to the factory default: 
1.  From the System Configuration menu, select Factory Default. (Main menu > 
Configuration > System Configuration > Factory Default). 
The Factory Default menu is displayed (
Figure 4-49
). 
ASMi-52 
Factory default 
Remote unit number          (1) 
1. Local factory default    ... 
2. Remote factory default  ... 
3. Local factory default W/O MNG  ... 
4. Remote factory default W/O MNG ... 
>  
ESC - prev. menu ; ! – main menu ; & – exit  
Figure 4-49.  Factory Default Menu 
2.  From the Factory Default menu, perform one of the following steps: 
 
Select Local Factory Default to reset the local ASMi-52. 
 
Select Remote Factory Default to reset the remote device. 
 
Select Local Factory Default W/O MNG to reset all parameters, except for 
the IP address, mask, default gateway and the manager list of the local 
ASMi-52. 
 
Select Remote Factory Default W/O MNG to reset all parameters, except 
for the IP address, mask, default gateway and the manager list of the 
remote ASMi-52. 
• 
 
Local/Remote Factory Default W/O MNG parameters are available only for the 
units equipped with the management LAN port. 
 
ASMi-52 displays the following message: 
Request to factory default !!! Confirm Y/N  
3. Type Y to confirm the reset. 
ASMi-52 resets all configuration parameters, except for the master clock 
(and IP values), to their default settings and restarts the system. 
Resetting the ASMi-52 Modem 
You can reset the SHDSL interface of the modem or repeater, or perform the 
overall reset of the modem. 
 
To reset the SHDSL interface or perform the overall device reset: 
1.  From the System Configuration menu, select Reset
The Reset menu appears (see 
Figure 4-50
). 