Quatech ABDB-ET Series Manuel D’Utilisation
Specifications
Page 58
AirborneDirect™ Ethernet Bridge User's Guide
100-8007-141G
Quatech, Inc. Confidential
Table 13 and Table 14 list power supply specifications for the Heavy-Duty Bridge.
Note:
The standard package Bridge is powered by the included AC adapter. Table 13
and Table 14 do not apply to the standard package.
and Table 14 do not apply to the standard package.
Table 13. Heavy-Duty Power Supply Specifications
Parameter
Min
Max
Normal Operating (J1455 – 12 V system)
9V
16V
Normal Operating (J1455 – 24 V system)
18V
32V
Cold Cranking (J1211)
4.5V
Jumper Start 5 minute (J1455 – 12 V system)
24V
Reverse Polarity (J1455 – 24 V system)
-24V
Max. Voltage
36V
Additional filtering is provided to accommodate the ISO 7637 Power Line Immunity and the SAE
J1113 Power Line Conducted Emissions requirements.
J1113 Power Line Conducted Emissions requirements.
Table 14. Heavy-Duty DC Specifications
Symbol Parameter
Min
Typ
Max
Units
V
Supply
Supply Voltage
4.5
32
V
I
Supply
Supply Current @ V
Supply
= 12 V
200
350
mA
I
Inrush
Peak Inrush Current For 25 ms
2.9
A