IPmux-16 Installation and Operation Manual 
Chapter 1  Introduction 
 
Functional Description 
1-11 
VLAN Support 
VLAN, according to IEEE 802.1p&q, adds four bytes to the MAC layer of the 
Ethernet frame. The contents of these bytes, MAC layer priority and VLAN ID, can 
be set by the user. In this mode, only VLAN format frames are sent and received 
by IPmux-16. The following figure describes the VLAN tag format.  
802.1D Tag Protocol Type 
(802.1QTagType)
81
00
user_priority
CF
I =
 0
VID
8
6
5
4
1
8
1
Priority
VLAN ID
 
Figure 1-9.  VLAN Tag Format 
UDP Support 
Table 1-2.  UDP Source Port as Destination Voice Port 
Field Length (Bits) 
Field Description 
Value 
2 bytes 
UDP Source Port*   
2 – 497d 
2 bytes 
UDP Destination Port   
2142d 
* The MSB of this field can be either 1 or 0 for inband end-to-end proprietary signaling. 
 
 
The UDP Source Port field is used for destination voice bundle indication.  
For example, if the destination is: 
Bundle 1 – 02, Bundle 2 – 03, Bundle 3 – 04, Bundle 4 – 05, etc. 
 
For more information about VLAN tagging, see IEEE Std 802.1 p&q. 
Packet Delay Variation 
Packets are transmitted at set intervals. Packet Delay Variation is the maximum 
deviation from the nominal time the packets are expected to arrive at the far end 
device. IPmux-16 has a buffer that compensates for the deviation from the 
expected packet arrival time to prevent IPmux-16 buffers from emptying out. 
Packet Delay Variation is an important network parameter. Large PDV (exceeding 
the jitter buffer configuration) will cause receive buffer underflows and errors at 
the E1/T1 level (see Figure 1-10). 
To compensate for large PDV, the PDVT (jitter) buffer should be configured to a 
higher value. 