IPmux-16 Installation and Operation Manual 
1-16 Technical Specifications
 
 
1.4 Technical Specifications 
E1 Modules 
E1 Port 
Ports 
Compliance 
Connector 
 
 
Data Rate 
Line Code 
Line Impedance 
Signal Levels 
 
 
 
Jitter Performance 
External Adapter 
Cable 
Up to 16 
ITU-T Rec. G.703, G.706, G.732, G.823 
Balanced: RJ-45 8 pin 
Unbalanced: TBNC 75Ω (an external adapter cable from 
TBNC to BNC is required) 
2.048 Mbps 
HDB3 
Balanced: 120Ω; Unbalanced: 75Ω 
Receive: 0 to –27 dB with LTU 
              0 to –10 dB without LTU 
Transmit Balanced: ±3V ±10% 
Transmit Unbalanced: ±2.37V ±10% 
ITU-T G.823 standard 
TBNC to BNC required for unbalanced interfaces 
 
 
 
E1 
Framing 
Compliance 
Framing 
Signaling 
G.704, G.706 
Passthrough, CRC4 MF, CAS MF 
CAS, CCS (transparent) 
 
 
 
T1 Modules 
 
 
T1 Port 
Ports 
Compliance 
Connector 
Data Rate 
Line Code 
Line Impedance 
Signal Levels 
 
 
 
Jitter Performance 
Up to 16 
ANSI T1.403, ITU-T Rec. G.703 
RJ-45, 8 pin 
1.544 Mbps 
B8ZS, B7ZS, AMI 
Balanced: 100Ω 
Receive: 0 to –27 dB 
Transmit: 0 dB, –7.5 dB, –15 dB, –22.5 with CSU 
               ±2.7V ± 10%, adjustable, measured in range 
                0 to 655 feet without CSU 
AT&T TR-62411, G.824 standards