RAD Data comm IPmux-16 Manuel D’Utilisation

Page de 99
Chapter 3  Operation 
IPmux-16 Installation and Operation Manual 
3-2  Operating Instructions
 
 
Table 3-1.  IPmux-16 System Indicators and Switches 
No Module Name  Type Function 
1 System  RDY 
LED  On: 
Device 
OK 
OFF: Self-test in progress 
Blinking: Malfunction detected 
System 
PS1/PS2 
LED 
On: Unit powered 
Off: Unit not powered 
System 
ALM 
LED 
Red: Alarm  
Off: No alarm 
Ethernet 
LINK 
LED 
Off: Link not active 
On: Line OK 
Ethernet 
ACT 
LED 
Off: No activity 
On: Frame being transferred on line 
Ethernet 
100M 
LED 
Off: 10 MHz 
On: 100 MHz 
Ethernet 
FDX 
LED 
Off: Half duplex 
On: Full duplex 
E1 
SYNC 
LED 
On: Port synchronized (no alarm) 
Off: Unframed - Signal loss or AIS  
 detected 
 
Framed - Signal loss, loss of frame or  
 
AIS detected  
Blinking: RDI detected (remote alarm) 
Rear panel  PS1/PS2 
Switch  Turns IPmux-16 power on and off 
3.3 Operating Instructions 
Turning IPmux-16 On – Without Control Terminal 
IPmux-16 power switches are located on the back panel, as shown in Figure 3-2.  
➤ 
To power up IPmux-16 without a terminal: 
•  Switch the PS1 power supply switch, located on the rear panel, to ON. 
IPmux-16 can be optionally equipped with a second power supply (PS2). If 
present, switch PS2 to ON. 
After power-up, check the unit LED indicators, located on the right side of the 
front panel, and the module indicators for proper operation (see Figure 3-1, 
Figure 3-2
, and Table 3-1)