Chapter 2  Installation 
IPmux-16 Installation and Operation Manual 
2-6  Installation and Setup
 
 
Table 2-4.  Alarm Connector Pinout 
Pin No. 
Signal Name 
Status 
1, 2, 6, 7 
Discrete line input 
 
Minor alarm 
Normally closed 
Major alarm  
Normally closed 
Major alarm 
Common contact 
8 GND 
 
Minor alarm 
Normally closed 
 
 
When a major alarm occurs, a relay between pins 4 and 5 will be closed. When a 
minor alarm occurs, a relay between pins 3 and 9  will be closed. 
 
The alarms that trigger the relay are listed in Chapter 3. The relay will be activated 
only if the specific Alarm trap is enabled (not masked). 
Connecting the Power 
IPmux-16 is available with either an AC or a DC power supply (Figure 2-2). 
➤ 
To connect the power: 
1.  Connect the power cord, supplied with IPmux-16, to PS1 on the IPmux-16 
front panel. If a redundant power supply is present, connect the ther power 
cord supplied to PS2. 
2.  Before connecting IPmux-16 to power, check that the ON/OFF switch(es) on 
the rear panel is (are) set to OFF. 
3.  Connect the power cord first to PS1 (and PS2) and then to the mains outlet. 
The outlet should be within 1.5 meters (five feet) of the unit. 
4.  The power cord must be plugged into an outlet with a protective ground 
(earth) contact. The protective action must not be negated by use of an 
extension cord without a protective conductor (grounding).  
 
Note