RAD Data comm IPmux-16 Manuel D’Utilisation

Page de 99
IPmux-16 Installation and Operation Manual 
Chapter 3  Operation 
 
Configuring IPmux-16 
3-15 
➤ 
To set the manager list parameters: 
1. Enter 1 to set the manager IP address: range of 0.0.0.0. to 255.255.255.255
2. Enter 3 to set the alarm trap: On or Off. Use the Spacebar to toggle between 
these two settings. When set to On, the alarm trap informs the manager of the 
occurrence of any alarm enabled in the Alarms Trap Mask screen. It informs 
the manager of both entry and exit from an alarm state. When OFF, no alarm 
trap will be sent regardless of the Mask defined in the Alarm Trap Mask screen. 
3. Enter 4 to set the system trap: On or Off. Use the Spacebar to toggle between 
these two settings. When set to On, the system trap informs the manager 
whenever there is a change in the system power-supply status, heat alarm. 
4.  To ping the manager, press P
5.  To access additional manager-list parameters, press N to go to the next 
manager-list window. 
Default Gateway 
Main menu 
↓ 
2. Configuration 
↓ 
1. General 
Configuration 
↓ 
3. Management 
Configuration 
↓ 
4. Default 
Gateway 
Default gateway defines the gateway to which management frames will be sent 
(when the manager is not in the host subnet). When a next hop is not defined in 
the connection parameters, the default gateway is used.  
➤ 
To configure the default gateway 
1. Type 4 (Default Gateway) in the Management Configuration menu. 
      DEFAULT GATEWAY 
 
1. Gateway IP     0.0.0.0 
ESC. Exit 
 
Select item from the menu. 
Figure 3-16.  Default Gateway Menu 
2. Type 1 and then type in the IP address of the default gateway.