Chapter 3  Operation 
IPmux-16 Installation and Operation Manual 
3-16 Configuring IPmux-16
 
 
Alarms Trap Mask 
Main menu 
↓ 
2. Configuration 
↓ 
1. General Configuration 
↓ 
3. Management 
Configuration 
↓ 
5. Alarms Trap Mask 
Enter 5 from the Management Configuration menu; the Alarms Trap Mask 
window will then be displayed (Figure 3-15). 
 
Alarms Trap Mask 
1.  Alarm ID (refer to Manual) 
 
2.  Trap Status   
 
 
 
Active 
 
ESC. Exit   
S. save 
ACTIVE ALARM TRAPS: 
 
1, 2, 6, 8 
Figure 3-17.  The Alarms Trap Mask Window  
Each of the IPmux-16 alarms can activate a trap toward the NMS. It is possible to 
enable/disable the trap operation for each one of the alarms, using the Alarm Trap 
Mask screen. 
➤ 
To define the Alarms Traps Mask: 
•  Type 3 (Alarms Trap Mask) in the Management Configuration Window.  
The Alarms Traps Mask window is displayed. 
➤ 
To activate/deactivate a trap generation for an alarm 
•  Type 1 and enter the alarm ID (see Table 3-1). The relevant range is 1-40.  
➤ 
To change the trap status: 
•  Type 2 (Trap status) and press <Spacebar> to toggle between ACTIVE 
(generate a trap) and MASKED (no alarms sent). The default for all traps is 
MASKED. 
Table 3-2.  IPmux-16 Alarms 
Alarm ID 
Alarm Description 
Trap Sent to NMS 
Dry Contact 
Loss of Signal (LOS Physical Layer)  
Alarm LOS 
1.3.6.1.4.1.164.6.1.3.0.7 
Major 
Loss of Frame (LOF Physical Layer)  
Alarm LOF 
1.3.6.1.4.1.164.6.1.3.0.8 
Major 
Alarm Indication Signal Received (AIS 
Line Physical Layer)  
Alarm AIS 
1.3.6.1.4.1.164.6.1.3.0.10 
Major 
Remote Defect Indication Received 
(RDI Line Physical Layer)  
Alarm RDI 
1.3.6.1.4.1.164.6.1.3.0.11 
Major