RAD Data comm IPmux-16 Manuel D’Utilisation

Page de 99
IPmux-16 Installation and Operation Manual 
Chapter 3  Operation 
 
Configuring IPmux-16 
3-41 
Table 3-3.  Alarms and Statistics (Cont.) 
Alarm Failure 
Comments 
Valid Modes 
FEBE 
Far End Block Error 
The number of seconds in which 
the FEBE indication is received 
from the remote E1 device. 
E1 CRC4 mode 
BES 
Bursty Errored Seconds (Errored 
Second type B) 
The number of seconds with 
from two to 319 CRC error 
events with no AIS nor SEF 
(Framing Bit Errors) error 
detection. 
Not applicable if Line Type is set 
to Unframed 
T1-ESF or 
E1-CRC4 modes 
DM 
Degraded Minutes 
A Degraded Minute is calculated 
by collecting all of the available 
seconds, subtracting any SESs 
and sorting the result in 60 
second groups. 
A Degraded Minute is a 60 
second group in which the 
cumulative errors during the 
60-second interval exceed 
1x10
-6
T1-ESF or 
E1-CRC4 modes 
ES 
Errored Second: If any error 
occurs during one second. 
Any second containing the 
following error events: 
CRC 
SEF (OOF) 
AIS (T1 only). 
If SES is also active (see below) 
ES runs for 10 seconds and then 