RAD Data comm IPmux-16 Manuel D’Utilisation

Page de 99
IPmux-16 Installation and Operation Manual 
Chapter 4  Troubleshooting and Diagnostics 
 
Troubleshooting 
4-3 
 
4.2 Troubleshooting 
The following table presents the event types as they appear on the Event Log File 
and lists the actions required to correct the event (alarm) indication. 
Table 4-2.  IPmux-16 Troubleshooting Chart 
Fault 
Probable Cause 
Remedial Action 
The E1/T1 equipment 
connected to IPmux-16 is not 
synchronized (E1/T1 level) with 
IPmux-16  
Configuration problems 
1.  Check IPmux-16 port 
configuration and, if 
necessary, other IPmux-16 
parameters. 
2.  Check E1/T1 physical 
connection (use loopbacks). 
Slips and errors in E1/T1 
equipment 
•  Ethernet port in switch and 
IPmux-16 are not in the same 
rate or duplex mode 
•  Ethernet port is set to work in 
half duplex mode (may cause 
extreme PDV because of 
collisions and backoffs) 
•  Timing configuration is not 
properly set (periodic buffer 
under/overflows – bundle 
connection status menu) 
•  Network PDV or Lost Frames 
1.  Check E1/T1 physical 
connection (use loopbacks) 
and E1/T1 statistics. 
2.  Check timing settings 
according to explanation in 
this manual. 
3.  Check switch and IPmux-16 
port configuration 
(negotiation, rate, duplex 
mode) and check Ethernet 
statistics. 
4.  Check PDV introduced by 
the network, and, if 
necessary, increase PDVT 
jitter buffer setting. 
Echo in voice 
 
1.  Check network delay and try 
to decrease it. 
2.  Try to decrease PDVT (jitter) 
buffer.