Chapter 4  Troubleshooting and Diagnostics 
IPmux-16 Installation and Operation Manual 
4-4  Diagnostic Tests
 
 
 
4.3 Diagnostic Tests 
Maintenance capabilities include external and internal loopbacks. 
Main Menu 
↓  
2. Configuration 
↓  
3. E1/T1 
Configuration 
↓  
1. Physical Layer 
Configuration 
➤ 
To run a loopback test: 
•  From the main menu press 2 (Configuration), 3 (E1/T1 Configuration) and 
then 1 (Physical Layer Configuration). 
•  Type 2 and press the spacebar on your keyboard to toggle between: 
Internal / External / Disable. 
−  Internal:  Data received from the IP network side will be looped back to 
the network transmit line. An unframed all ‘1’ code (AIS) will be 
transmitted in the E1/T1 Tx path toward the PBX. Incoming data from 
the PBX will be ignored. 
−  External:  Data received from the PBX at the receive E1/T1 line will be 
looped back to the E1/T1 Tx path (toward the same PBX), and will 
continue its way to the IP network. Data coming from the IP network will 
be ignored. 
−  Disable:  No loopback. Regular operation.  
Default value: Disable 
External Loop 
IPmux-16 can be set to an external loop to test the connection between the E1/T1 
port and the PBX (refer to Chapter 3). 
In this mode, data coming from the PBX is both looped back to the PBX and 
transmitted forward to the IP network. 
This mode can also be entered by a T1 FDL line loopback command. 
 
PBX
IPmux-16
External Loop
 
Figure 4-1.  External Loop 
Internal Loop 
The E1/T1 module can be set to an internal loop to test the connection between 
the E1/T1 port and the IP network (refer to Chapter 3).  
In this mode (E1/T1 only), data coming from the IP network is both looped back to 
the IP network and an AIS pattern is transmitted forward to the PBX connected to 
the E1/T1 port.