 Electrical 
Installation
Alarm Input Connections
Alarm Input Connections
Installation Summary
n
n
n
n
Precautions
CAUTION!   
W
IRE
 
LOOP
 
RESISTANCE
 
MUST
 
BE
 
LESS
 
THAN
 8 
OHMS
 (
OR
 
ABOUT
 250 
FT
OF
 22 AWG ABAM 
CABLE
TO
 
ENSURE
 
DETECTION
 
OF
 
CONTACT
 
CLOSURE
. L
ONG
 
WIRES
 
SHOULD
 
BE
 
SHIELDED
 
TO
 
PREVENT
 
FALSE
 
ALARMS
 
FROM
 
INDUCED
 
VOLTAGES
WARNING!   
D
O
 
NOT
 
APPLY
 
EXTERNAL
 
VOLTAGE
 
TO
 A
LARM
 I
NPUT
 
CONNECTOR
T
HIS
 
INTERFACE
 
IS
 
DESIGNED
 
FOR
 
OPERATION
 
WITH
 
EXTERNAL
 
SWITCHES
 
OR
 
RELAYS
 
PROVIDING
 
ISOLATED
 
CONTACTS
 
WITH
 
MINIMUM
 
CONTACT
 
RATINGS
 
OF
 60V DC @ 10 
M
A.
Tools and Materials
Obtain the following tools and materials:
Pliers, needle nose
Cutters, diagonal
Wire stripper, 16-26 AWG
Continuity tester
Volt-ohm meter
16 to 26 AWG insulated, shielded copper wire for alarm connections, as required by standard 
wiring practices.