Turn off the projector, and unplug the AC power cord from the 
AC outlet.
First, clean up the dust on the projector and around the air 
vents.
1
Press ▼ downwards on the filter cover to release the latch 
and open the filter cover.
Put the new one back into the position and close the filter 
cover. Make sure that the filter cartridge is properly and fully 
inserted.
5
CAUTION
Make sure the filter cartridge is inserted in the projector. If 
the filter cartridge is not inserted, the projector cannot be 
turned on. 
Do not put anything into the air vents. Doing so may result 
in malfunction of the projector.
4
Reset the filter counter and the scroll counter (p.68).
6
Filter cover
Pull out the filter cartridge. When taking out the filter cartridge, 
put your finger on the filter cartridge’s tab and then pull.
Latch
Filter cartridge
Tab
RECOMMENDATION
We recommend avoiding dusty/smoky environments when 
operating the projector . Usage in these environments may 
cause a poor image quality .
When using the projector under dusty or smoky conditions, 
dust may accumulate on a lens, liquid crystal panels, or optical 
elements inside the projector. Such condition may degrade the 
quality of the projected image.
When the symptoms above are noticed, contact your authorized 
dealer or service center for proper cleaning.
ORDER REPLACEMENT FILTER CARTRIDGE
Replacement  filter  cartridge  can  be  ordered  through  your  dealer. 
When ordering, give the following information to the dealer.
 
   
Model No . of your projector
      PLC-WM5500, PLC-WM5500L
 
 
 
Replacement Filter Cartridge Type No .
      POA-FIL-00          
(Service Parts No. 610 346 9034)
Connect  the AC  power  cord  to  the  projector  and  turn  on  the 
projector.
7
Maintenance and Care
Replacing the Filter Cartridge