Canon WX6000 Manuel D’Utilisation

Page de 240
Setting Up the Network
186
Setting Projector Information [Projector info.]
From [Projector info.] in the settings window, you can set the names and location 
names which are used to identify projectors when multiple projectors are installed on 
the network. For the setting procedure, refer to 
Item
Explanation
Factory default setting
SNMP
Select the SNMP function version. If OFF is 
selected, the SNMP function will be turned 
off and the other settings in this window 
cannot be changed.
OFF
Receive community
Enter the community name which will 
receive projector information in 1-byte 
alphanumeric characters and symbols (1 - 
15 characters).
<Blank>
Password
Enter the community settings password in 
1-byte alphanumeric characters and sym-
bols (8 - 15 characters). This is also used 
as the password for trapping. It can be set 
only when the SNMP version is V3.
<Blank>
Confirm password
For confirmation, enter the same password 
as you entered in [Password].
<Blank>
SNMP trap
Select the type of error to trap. When any of 
the checkboxes is turned on, it becomes 
possible to set [Trap IP address] and [Trap 
community].
OFF (no checkmarks)
Trap IP address
Enter the IP address to send information to 
when trap occurs. Enter in 1-byte numbers.
0.0.0.0
Trap community
Enter the community name which will send 
information when trap occurs. Enter in 1-
byte alphanumeric characters and symbols 
(1 - 15 characters).
<Blank>
Item
Explanation
Factory default setting
Projector name
Enter the projector name in 1-byte alphanu-
meric characters and symbols (1 - 63 char-
acters).
WUX5000 / WUX4000 / 
WX6000 / SX6000
Location
Enter the projector installation location in 1-
byte alphanumeric characters and symbols 
(0 - 63 characters).
<Blank>