■Setting Projector Information [Projector info.]
From [Projector info.] in the settings window, you can set the names and location
names which are used to identify projectors when multiple projectors are installed on
the network. For the setting procedure, refer to
names which are used to identify projectors when multiple projectors are installed on
the network. For the setting procedure, refer to
Item
Explanation
Factory default setting
SNMP
Select the SNMP function version. If OFF is
selected, the SNMP function will be turned
off and the other settings in this window
cannot be changed.
selected, the SNMP function will be turned
off and the other settings in this window
cannot be changed.
OFF
Receive community
Enter the community name which will
receive projector information in 1-byte
alphanumeric characters and symbols (1 -
15 characters).
receive projector information in 1-byte
alphanumeric characters and symbols (1 -
15 characters).
<Blank>
Password
Enter the community settings password in
1-byte alphanumeric characters and sym-
bols (8 - 15 characters). This is also used
as the password for trapping. It can be set
only when the SNMP version is V3.
1-byte alphanumeric characters and sym-
bols (8 - 15 characters). This is also used
as the password for trapping. It can be set
only when the SNMP version is V3.
<Blank>
Confirm password
For confirmation, enter the same password
as you entered in [Password].
as you entered in [Password].
<Blank>
SNMP trap
Select the type of error to trap. When any of
the checkboxes is turned on, it becomes
possible to set [Trap IP address] and [Trap
community].
the checkboxes is turned on, it becomes
possible to set [Trap IP address] and [Trap
community].
OFF (no checkmarks)
Trap IP address
Enter the IP address to send information to
when trap occurs. Enter in 1-byte numbers.
when trap occurs. Enter in 1-byte numbers.
0.0.0.0
Trap community
Enter the community name which will send
information when trap occurs. Enter in 1-
byte alphanumeric characters and symbols
(1 - 15 characters).
information when trap occurs. Enter in 1-
byte alphanumeric characters and symbols
(1 - 15 characters).
<Blank>
Item
Explanation
Factory default setting
Projector name
Enter the projector name in 1-byte alphanu-
meric characters and symbols (1 - 63 char-
acters).
meric characters and symbols (1 - 63 char-
acters).
WUX5000 / WUX4000 /
WX6000 / SX6000
WX6000 / SX6000
Location
Enter the projector installation location in 1-
byte alphanumeric characters and symbols
(0 - 63 characters).
byte alphanumeric characters and symbols
(0 - 63 characters).
<Blank>