2.9 RFID Module Setting
 
2-74 
 
How to Enter RFID Module Setting Mode 
Turn on the printer while pressing the [FEED] and [PAUSE] keys at the same time.  Hold both keys until the 
“<1>DIAG. Vx.x” Message appears. 
 
 
Press the [RESTART] key or [FEED] key until “<10>RFID” appears. 
 
2.9.1  RFID Read Test 
This parameter is to choose whether to perform an RFID read test.  When using an RFID module for the 
first time, or when performing an RFID read test after performing a parameter clear, it is necessary to set 
the RFID module parameters in advance.  Refer to Section 2.9.2. 
When “<10>RFID” appears, press the [PAUSE] key. 
 
 
 
 
 
 
 
 
 
<Read Test Procedure> 
  1)  Place a TOSHIBA-recommended RFID tag as close as the antenna.  
 
NOTE: Available RFID tag 
 B-SX708-RFID-U2-EU-R, 
B-SX708-RFID-U2-CN-R: EPC C1 Gen2 
 
  2)  The printer enters the read test mode, and a read test is performed each time the [PAUSE] key is 
pressed. The read data on the tag is displayed on the LCD message display. If the tag cannot be 
read, “RFID TIMEOUT” or “RFID READ ERROR” is displayed. Only the tags selected by the RFID 
tag type selection can be read. An RFID tag read error will result if the type of the tag to be read and 
the type of the tag selected by the RFID tag type selection do not match. Make sure the RFID tag 
type has been selected before the read test is started. 
   
Example (Q value = 0) 
 
 
 
   
Example (Q value = 1) 
 
 
 
   
The data, displayed in hex. numbers.  Displayed data is an EPC code in the EPC area.  
When the RFID tag contains data of 16 digits or more, the first 16 digits are displayed.  When data 
volume is less than 16 digits, the vacant digits will be filled with spaces.  
   
In the case the Q value is set to 1 or greater, the AGC value of a read tag, enclosed with 
parentheses, is displayed on the right most place on the lower line.  Therefore, 14-byte data is 
displayed in hex. code.  
   
Additionally, if more than one tag is read at one time, especially when short-pitch tags are used, 
pressing the [FEED] or [RESTART] key shows the other tags’ data.  Among them, a tag with the 
highest AGC value is considered to be positioned just above the antenna. 
 
<10>RFID 
READ TEST     OFF 
<10>RFID 
READ TEST      ON 
[PAUSE] 
The next menu will appear without
performing a read test.  Refer to
Section 2.9.2. 
[PAUSE]
A read test will be performed. 
As this read test is intended to just read a tag, if you
would like to perform a write test, use RFID Analyse
Tool.  Refer to Section 5. 
[FEED] or [RESTART]
<1>DIAG.   Vx.x 
1234567890123456 
6543210987654321 
1234567890123456 
65432109    (0E)