Emerson AXP1406 Manuel D’Utilisation

Page de 148
Power Entry Module Analog Sensors
FRU Information and Sensor Data Records
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
129
   
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask, 
Settable threshold mask (bytes 
19, 20)
0x3F, 0x3F
Upper and Lower Non-Critical, 
Critical and Non-Recoverable 
Thresholds are Readable and 
Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and 
Non-Recoverable thresholds
0x86, 0x7A, 0x73
(42.076, 38.308, 36.11) Volts
Upper Non-Critical, Critical and 
Non-Recoverable thresholds
0xE6, 0xEF, 0xF3
(72.22, 75.046, 76.302) Volts
Table 2-139 Sensor No. 12 +7.5 V PEM
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+7.5 V PEM
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask, 
Settable threshold mask (bytes 
19, 20)
0x3F, 0x3F
Upper and Lower Non-Critical, 
Critical and Non-Recoverable 
Thresholds are Readable and 
Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and 
Non-Recoverable thresholds
0x7D, 0x74, 0x6A
(6.5, 6.032, 5.512) Volts
Upper Non-Critical, Critical and 
Non-Recoverable thresholds
0xA4, 0xAE, 0xB7
(8.528, 9.048, 9.516) Volts
Table 2-138 Sensor No. 11 +48.0 V Feed (continued)
Feature
Raw Value/Description
Interpreted Value