Emerson AXP1406 Manuel D’Utilisation

Page de 148
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records
Power Entry Module Analog Sensors
130
   
Table 2-140 Sensor No. 13 +8 V PEM Feed 2
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+8 V PEM Feed 2
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask, 
Settable threshold mask (bytes 
19, 20)
0x3F, 0x3F
Upper and Lower Non-Critical, 
Critical and Non-Recoverable 
Thresholds are Readable and 
Settable
Reading Type
Unsigned
Lower Non-Critical, Critical and 
Non-Recoverable thresholds
0x87, 0x7D, 0x74
(7.02, 6.5, 6.032) Volts
Upper Non-Critical, Critical and 
Non-Recoverable thresholds
0xAE, 0xB7, 0xC1
(9.048, 9.516, 10.036) Volts
Table 2-141 Sensor No. 15 +8 V PEM Feed 1
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+8 V PEM Feed 1
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Power Supply
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only