Connections and Installation
Telnet Configuration 
Password
Setting the Telnet configuration password prevents unauthorized access
of the setup menu via a Telnet connection to port 9999.  The password 
is limited to 32 characters. Option 7 allows the user to change the telnet 
configuration password.
Testing the IP 
Address 
Configuration
Once the IP address is assigned, you should test the IP address 
configuration to be sure it works as configured.
Prerequisite 
This procedure assumes that you have configured the device server with
an IP address. 
Procedure 
1. 
Access the command line of a PC or other networked device. 
2. 
Issue the following command:  ping ip-address (where ip-address  
 
is the address you assigned to the device server). 
Example:
ping 192.168.1.110
A reply should be returned. 
LAN Module 
Configuration Using 
a Telnet Connection
To configure the LAN Module over the network, establish a Telnet
connection to port 9999.  From the Windows Start menu, click Run and 
type the following command, where x.x.x.x is the IP address and 9999 is 
the LAN Module’s fixed network configuration port number.
 
 
 
 
telnet x.x.x.x 9999
Note:  Be sure to include a space between the IP address and 9999.
The default IP Address is 192.168.1.110, so the command should look 
like “telnet 192.168.1.110 9999”.  At login, type “root” for the username 
and “1234” for the password. This command will launch the configuration
menu. After the first sentence appears, press [Enter] to go into the setup