Panasonic PT-AE1000U Manuel D’Utilisation

Page de 56
PICTURE Menu
E
NGLISH
 - 33
Settings
J
MPEG NR
You can switch the automatic noise reduction 
system for MPEG format images on/off. The 
system minimizes block noise and mosquito noise 
to eliminate jagged edges, providing an overall 
smoother image. Press I H to select the required 
setting.
• ON:
Active
• OFF:
Deactive
J
CINEMA REALITY
You can switch the automatic image synchronizer 
on/off for 24 frames a second images, such as 
movies. Press I H to select the required setting.
• ON:
Active
• OFF:
Deactive
J
TV-SYSTEM
When the video signal is changed, the setting switches 
automatically.
You can switch the setting manually to match the video 
data. Press I H to cycle through the options.
You can save the adjusted PICTURE settings with up to 
5 in each of 2 signal groups.
1. Adjust the different items of the PICTURE menu.
2. Select MEMORY SAVE and press ENTER.
3. Select MEMORY1 - 5 to save and press ENTER.
 
The confirmation screen is displayed.
 
 : In use
 : Not in use
 
Select ALL DELETE to clear all the saved 
settings.
4. Select OK and press ENTER.
 
To cancel, select CANCEL and press ENTER
or press the RETURN button.
You can access saved settings instantly. See “Loading 
a saved setting” on page 25.
1. Select the required setting from MEMORY1 - 5.
 
Undefined setting will not be displayed.
2. Press ENTER to activate the selected setting.
The current selected signal is displayed when 
PC/COMPONENT/HDMI equipment is connected.
NOTE:
 
MPEG NR is for MPEG images only.
 
MPEG NR is not available with PC and HDMI 
(VGA60) signals.
NOTE:
 
CINEMA REALITY is available with interlace 
signals only.
 
If the CINEMA REALITY is different from the 
required setting of the image, select OFF.
AUTO
SECAM
PAL-N
PAL-M
NTSC
NTSC 4.43
PAL
MEMORY SAVE
VIDEO, S-VIDEO, COMPONENT, 
HDMI (not including VGA60), 
1 125 (1 080)/50i, 1 125 (1 080)/60i, 
1 125 (1 080)/50p and 
1 125 (1 080)/60p signals in PC 
connection
MEMORY1 - 5
VGA60 in HDMI connection, PC not 
including 1 125 (1 080)/50i, 
1 125 (1 080)/60i, 1 125 (1 080)/50p 
and 1 125 (1 080)/60p
MEMORY1 - 5
MEMORY LOAD
NOTE:
 
If you have not saved any settings, MEMORY1 - 5 
will not be displayed.
SIGNAL MODE
NOTE:
 
See “List of compatible signals” on page 45.
PT-AE1000U.book  Page 33  Monday, October 16, 2006  1:40 PM