Hoshizaki KM-1301SAH/3 Manuel D’Utilisation

Page de 84
43
C. Performance Data
1. KM-1301SAH (air-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in 
bold 
should be used for reference only.
. We reserve the right to make changes in specifications and design without prior 
notice.
70/21
1329
603
1281
581
1188
539
80/27
1292
586
1217
552
1109
503
90/32
1281
581
1164
528
1060
481
lbs./day   kg./day
100/38
1253
568
1140
517
965
438
70/21
80/27
90/32
watts
100/38
70/21
605
2.29
481
1.82
429
1.62
80/27
510
1.93
318
1.21
331
1.25
90/32
481
1.82
183
0.69
167
0.63
gal./day    m
3
/day
100/38
345
1.30
179
0.68
152
0.58
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
255
17.9
273
19.2
298
20.9
80/27
269
18.9
297
20.9
321
22.6
90/32
273
19.2
317
22.3
342
24.0
PSIG     kg/cm
2
G
100/38
278
19.5
323
22.7
365
25.7
70/21
50
3.5
50
3.5
53
3.8
80/27
50
3.5
50
3.5
55
3.9
90/32
50
3.5
50
3.5
55
3.8
PSIG     kg/cm
2
G
100/38
52
3.6
51
3.6
59
4.1
20,300  BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
32
36
32
33
35
32
34
2.1
4.7
3.1
3.9
2.9
2.1
4.1
31
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC 
CONSUMPTION
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP. 
(ºF/ºC)
50/10
70/21
90/32
2193
2166
2174
2180
2197
2160
2164
2166
35
37
38
41
2222
2257
2253
2320
HARVEST CYCLE TIME
HEAD PRESSURE
3.7
3.1
3.9
2.1
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE
ENG.F-011.1.0205