Hoshizaki KM-1301SAH/3 Manuel D’Utilisation

Page de 84
44
2. KM-1301SAH3 (air-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in 
bold 
should be used for reference only.
. We reserve the right to make changes in specifications and design without prior 
notice.
70/21
1298
589
1257
570
1162
527
80/27
1267
575
1204
546
1086
493
90/32
1257
570
1159
526
1049
476
lbs./day   kg./day
100/38
1225
556
1133
514
947
430
70/21
80/27
90/32
watts
100/38
70/21
511
1.94
415
1.57
367
1.39
80/27
438
1.66
287
1.09
286
1.08
90/32
415
1.57
181
0.68
159
0.60
gal./day    m
3
/day
100/38
305
1.15
176
0.67
139
0.53
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
254
17.9
272
19.1
296
20.8
80/27
268
18.8
295
20.8
319
22.4
90/32
272
19.1
315
22.1
339
23.8
PSIG     kg/cm
2
G
100/38
276
19.4
321
22.5
361
25.4
70/21
48
3.4
49
3.4
52
3.6
80/27
49
3.4
50
3.5
54
3.8
90/32
49
3.4
51
3.6
55
3.8
PSIG     kg/cm
2
G
100/38
50
3.5
52
3.6
58
4.1
20,200  BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
33
37
33
34
36
33
35
2.1
4.2
2.9
3.6
2.8
2.1
3.8
32
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC 
CONSUMPTION
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP. 
(ºF/ºC)
50/10
70/21
90/32
2123
2128
2178
2220
2224
2090
2119
2128
36
39
40
43
2152
2187
2236
2250
HARVEST CYCLE TIME
HEAD PRESSURE
3.4
2.9
3.6
2.1
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE
ENG.F-011.1.0205