6 – Removal/Replacement
Cross-Connect Blades
6-12
59043-03 A
D
6.4.1
Removing a CC Blade
To remove a CC blade, do the following:
1.
Power down the switch. Isolate the switch from the fabric. Open a Telnet 
session and enter the Shutdown command. Disconnect the power cords 
from the power supplies.
telnet <ip_address>
SANbox2 Login: admin
Password: password
Sanbox2-64 #> admin start
Sanbox2-64 (admin) #> shutdown
The switch will shutdown. Please confirm (y/n): [n] y
Shutdown in progress...
Please wait at least 20 seconds before powering off
the switch or loss of data may result.
2.
Label the Fibre Channel port cables by slot number and port number. I/O 
blade slots are numbered 1–4 and 6–9. Ports on each I/O blade are 
numbered 0–7 from top to bottom.
3.
Put on an ESD wrist strap. Connect it to the ground jack on the CPU module 
or to another chassis ground point. Disconnect Fibre Channel port cables.
4.
Disconnect Ethernet and serial cables.
5.
Remove the switch from the rack. Using a crosshead screw driver, remove 
the screws that secure the switch brackets to the rack. Slide the switch out 
of the rack until the rail latches drop down to stop the switch. Lift up on the 
latches on both sides and finish removing the switch.
WARNING!!Two people are required to safely lift and install the switch into a 
cabinet. To avoid personal injury or damage to the switch, 
arrange for assistance.
AVERTISSEMENT!!
Deux personnes doivent soulever et installer le commutateur 
dans une armoire. Pour éviter toute blessure personnelle ou 
dommage à l'interrupteur, demander de l'assistance.
WARNUNG!!
Es sind zwei Personen erforderlich, um den Switch sicher 
anzuheben und in ein Gehäuse zu installieren. Zur 
Vermeidung von Verletzung oder Beschädigung des 
Switches Unterstützung veranlassen.