Q-Logic 64 Manuel D’Utilisation

Page de 244
2 – General Description
Chassis Controls and LEDs
2-4
59043-03 A
D
2.2
Chassis Controls and LEDs
The Maintenance button on the CPU module, shown in 
, is the only 
chassis control and is used to reset a switch or to recover a disabled switch. 
Power is applied to the switch logic circuitry when one or both power supply 
modules are connected to a 110 or 230 VAC power source. The chassis LEDs are 
located on the CPU module and provide information about the switch’s 
operational status. The chassis LEDs provide information about the switch’s 
operational status. The chassis LEDs include the Input Power LED, Heartbeat 
LED, Over Temperature LED, and the Fan Fail LED. Refer to 
 for information about power supply LEDs and to 
 for information about the Port Status LED.
Figure 2-3.  Chassis Controls and LEDS
2.2.1
Maintenance Button
The Maintenance button is dual function control on the CPU module that resets 
the switch or places the switch in maintenance mode. Maintenance mode sets the 
IP address to 10.0.0.1 and provides access to the switch for maintenance 
purposes when flash memory or the resident configuration file is corrupted. Refer 
to 
 for information about maintenance mode.
Maintenance 
Button
Chassis LEDs
Power 
Supply LEDs
Ethernet 
Port LEDs