Q-Logic 64 Manuel D’Utilisation

Page de 244
2 – General Description
Chassis Controls and LEDs
59043-03 A
2-5
D
2.2.1.1
Resetting a Switch
To reset the switch, use a pointed tool to press and release (less than 2 seconds) 
the Maintenance button. The switch will respond as follows:
1.
All of the chassis LEDs will illuminate and then extinguish leaving only the 
Input Power LED illuminated.
2.
After approximately 1 minute, the power-on self test begins illuminating all 
chassis LEDs.
3.
When the POST is complete, the chassis LEDs extinguish leaving the Input 
Power LED illuminated and the Heartbeat LED flashing once per second.
2.2.1.2
Placing the Switch in Maintenance Mode
To place the switch in maintenance mode, do the following:
1.
Isolate the switch from the fabric.
2.
Press and hold the Maintenance button with a pointed tool for about 2 
seconds. When the Input Power LED alone is illuminated, release the 
button.
3.
After approximately 1 minute, the power-on self test begins illuminating all 
chassis LEDs.
4.
When the POST is complete, the chassis LEDs extinguish leaving the Input 
Power LED and the Heartbeat LED illuminated. The Heartbeat LED 
illuminates continuously while the switch is in maintenance mode.
To exit maintenance mode and return to normal operation, press and release the 
Maintenance button to reset the switch.