Nortel Networks CVX 600 Manuel D’Utilisation

Page de 168
Audible and Visual Alarm Interface Specifications
A-16
296-1011-202 Rel. 5.0, Doc. Rev. 02.01 
CVX 600 Hardware Installation Guide
Audible and Visual Alarm Interface Specifications
The following figure shows the alarm interface connector with both styles of 
labeling.
Alarm Interface Connector  
Signals
The following table lists the positions and signal names on the alarm interface 
connector: 
Reference
See 
 on 
 for more information.
Position
Audible Signal
Position
Visual Signal
1 (Signal)
Critical
7 (Signal)
Critical
2 (Return)
Return
8 (Return)
Return
3 (Signal)
Major
9 (Signal)
Major
4 (Return)
Return
10 (Return)
Return
5 (Signal)
Minor
11 (Signal)
Minor
6 (Return)
Return
12 (Return)
Return
Visual 
Alarms
A
udib
le
Alarms
Critical
Return
Major
Minor
Return
Return
Critical
Return
Major
Minor
Return
Return
Visual
Alarms
A
udib
le
Crit
Ret
Maj
Min
Ret
Ret
Crit
Ret
Maj
Min
Ret
Ret
CVX-0176C
New Labeling Style
Older Labeling Style