Connecting Alarms
296-1011-202 Rel. 5.0, Doc. Rev. 02.01
2-5
Chassis Connections
Reference
For pinout assignments, see 
ATM PVPC 
PVCC Up
Minor
The PVPC/PVCC has been successfully created.
ATM PVPC 
PVCC 
Minor
The PVPC/PVCC is down.
ATM APS 
Switchover
Minor
A link failure caused the PHY driver to turn on the 
redundant PHY.
Sonet/SDH 
Alarm Sdber
Major
The specified STM-1 is in Signal Degrade Bit Error 
Rate alarm. The value set in the 
SigDegradeThreshold attribute for this line has 
been exceeded.
Sonet/SDH 
Alarm Sfber
Major
The specified STM-1 is in Signal Failure Bit Error 
Rate alarm. The value set in the 
SigFailureThreshold attribute for this line has been 
exceeded.
Sonet/SDH 
Alarm Sdber 
Clear
Major
The specified STM-1 is not in Signal Degrade Bit 
Error Rate alarm. The Signal Degrade Bit Error Rate 
is now below the SigDegradeThreshold value set in 
the configuration.
Sonet/SDH 
Alarm Sfber 
Clear
Major
The specified STM-1 is not in Signal Failure Bit Error 
Rate alarm. The Signal Failure Bit Error Rate is now 
below the SigFailureThreshold value set in the 
configuration.
Alarm Type
Severity
Description