Chassis Controls and LEDs
Chassis controls include the power supply On/Off switches and the Maintenance 
button as shown in 
. The Maintenance button is used to recover a 
disabled switch. The chassis LEDs provide information about the switch’s 
operational status. The chassis LEDs include the Over Temperature LED, Fan Fail 
LED, Heartbeat LED, and the Input Power LED.
Figure 2-2.  Chassis Controls and LEDS
2.1.1
Power Switches
Each power supply has an On/Off switch that controls power to the switch logic 
circuitry. To apply power to the switch, place both switches in the On position.
2.1.2
Maintenance Button
The Maintenance button is a momentary switch on the front panel. Its purpose is 
to place the switch in maintenance mode. Maintenance mode sets the IP address 
to 10.0.0.1 and provides access to the switch for maintenance purposes when 
flash memory or the resident configuration file is corrupted. Refer to 
 for information about maintenance mode.
To place the switch in maintenance mode, do the following:
1.
Isolate the switch from the fabric. Open a Telnet session, and enter the 
Shutdown command. Refer to 
2.
Place both power supply switches in the Off position.