Q-Logic SB2A-16B Manuel D’Utilisation

Page de 214
2 – General Description
Chassis Controls and LEDs
59021-09 A
2-3
0
3.
Press and hold the Maintenance button with a pointed, then place one of the 
power supply switches in the On position. You can release the Maintenance 
button after the Input Power LED illuminates. When the switch is in 
maintenance mode, the Heartbeat LED illuminates continuously. Refer to 
 for information about the Input Power LED and 
the Heartbeat LED.
To return to normal operation, power cycle the switch.
2.1.3
Chassis LEDs
The chassis LEDs shown in 
 provide status information about switch 
operation. Refer to 
 for information about port LEDs. 
 for information about power supply LEDs.
Figure 2-3.  Chassis LEDs
2.1.3.1
Over Temperature LED (Amber)
The Over Temperature LED provides status information about the air temperature 
inside the switch. This LED illuminates to indicate that the switch logic circuitry is 
overheating. Refer to 
 for information about 
troubleshooting over temperature conditions.
2.1.3.2
Fan Fail LED (Amber)
The Fan Fail LED indicates operational status of all fans. This LED illuminates if 
the speed of any fan falls below the normal range. Removing a fan will not 
illuminate the Fan Fail LED. Refer to 
 for 
information about troubleshooting fan failure conditions.
Over Temperature LED
(Amber)
Input Power LED
(Green)
Fan Fail LED
(Amber)
Heartbeat LED
(Amber)