Q-Logic SANBOX Manuel D’Utilisation

Page de 252
5 – Fibre Alliance MIB Objects
59047-03  B
5-9
A
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
Overall status of the connectivity unit. The goal of this object is to be the single 
poll point to check the status of the connunit. If there is any other component that 
has warning, then this should be set to warning. any of these values may occur 
with any of the ConnUnitState values.
Syntax
INTEGER
Access
read-only
Status
mandatory
Return Value
Refer to 
 for connectivity unit return values. Return value will be OK 
(3), unless one or more of the following occurs.
Table 5-3. Connectivity Unit Return Values
Status
Return Value
If one power supply is reporting Bad and/
or not installed
warning (4)
If both power supplies are reporting Bad 
and/or not installed
failed (5)
If one or more cooling fan failed
warning (4)
If all cooling fans failed
failed (5)
If temperature status = "Warm" 
warning (4)
If temperature status = "Overheating"
failed (5)
If any port down
warning (4)
If POST failed 
failed (5)
If switch Offline or in Diagnostics mode
warning (4)