Q-Logic SANBOX Manuel D’Utilisation

Page de 252
5 – Fibre Alliance MIB Objects
59047-03  B
5-11
A
connUnitUrl (1.3.6.1.3.94.1.6.1.10)
URL to launch a management application, if applicable. Otherwise, it’s an empty 
string. In a standalone unit, this would be the same as the top-level URL. This has 
the same definition as systemURL for keywords. If write is not supported, then the 
return value is invalid. This value will be retained across boots.
Syntax
DisplayString
Access
read-write
Status
mandatory
Return Value
The switch IP address. For example, http://10.0.0.1. Writes not supported, 
returns 'NoSuchName".
connUnitDomainId (1.3.6.1.3.94.1.6.1.11
24 bit Fibre Channel address ID of this connectivity unit, right justified with leading 
zeros if required. This should be set to the Fibre Channel address ID, or if it is a 
switch, it would be set to the Domain Controller address. If this value is not appli-
cable, return all bits set to one.
Syntax
OCTET STRING (SIZE(3))
Access
read-only
Status
mandatory
Return Value
The domain controller address. For example, FF FC 65.