Q-Logic 5600 Manuel D’Utilisation

Page de 336
5 – Managing Ports
Testing Ports
5-18
59097-02 B
S
„
Node-to-Node (Online) - The Node-to-Node test verifies communications 
between the port and its device node or device loop. The port being tested 
must be online and connected to a remote device. The port passes the test if 
the frame that was sent by the ASIC matches the frame that was received. 
This test does not disrupt communication on the selected port. This test 
requires that the port be online, and therefore, does not disrupt 
communication.
To run the internal, external, or online port loopback test on a port, do the 
following:
1.
In the faceplate display, select the port to be tested.
2.
Open the Port menu and select Port Loopback Test to open the Port 
Loopback Test dialog.
3.
In the Test Selection area, click the radio button for the type of loopback test 
to be run (Internal, External, or Online). If you choose the internal or external 
test, SANsurfer Switch Manager will prompt you to confirm that the port state 
needs to be changed to the diagnostic state. Click the OK button and 
SANsurfer Switch Manager will change the port state.
4.
Enter the frame count, frame size, and click a test pattern radio button. You 
may use the default pattern or enter an 8-digit pattern (hex). For online test, 
you can check the Terminate Test Upon Error check box if you want the 
test to stop should it encounter an error.
5.
Click the Start Test button to begin the test. The Test Results area displays 
the test status, number of frames sent, and number of errors found.
6.
To test another port, open the Select Port pull-down menu and select 
another port (number) and test type (Internal, External, or Online) in the Test 
Selection area.
7.
Click the Start Test button to begin the next test. Observe the results in the 
Test Results area.