Q-Logic 5600 Manuel D’Utilisation

Page de 336
A – Command Line Interface
Set Config Command
A-74
59097-02 B
S
The following is an example of the Set Config Threshold command:
SANbox xxxx #> admin start
SANbox xxxx  (admin) #> config edit
SANbox xxxx (admin-config) #> set config threshold
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
ThresholdMonitoringEnabled     (True / False)              [False     ]
  
CRCErrorsMonitoringEnabled     (True / False)              [True      ]
  RisingTrigger                (decimal value, 1-1000)     [25        ]
  FallingTrigger               (decimal value, 0-1000)     [1         ]
  SampleWindow                 (decimal value, 1-1000 sec) [10        ]
DecodeErrorsMonitoringEnabled  (True / False)              [True      ]
  RisingTrigger                (decimal value, 1-1000)     [200       ]
  FallingTrigger               (decimal value, 0-1000)     [0         ]
  SampleWindow                 (decimal value, 1-1000 sec) [10        ]
ISLMonitoringEnabled           (True / False)              [True      ]
  RisingTrigger                (decimal value, 1-1000)     [2         ]
  FallingTrigger               (decimal value, 0-1000)     [0         ]
  SampleWindow                 (decimal value, 1-1000 sec) [10        ]
LoginMonitoringEnabled         (True / False)              [True      ]
  RisingTrigger                (decimal value, 1-1000)     [5         ]
  FallingTrigger               (decimal value, 0-1000)     [1         ]
  SampleWindow                 (decimal value, 1-1000 sec) [10        ]
LogoutMonitoringEnabled        (True / False)              [True      ]
  RisingTrigger                (decimal value, 1-1000)     [5         ]
  FallingTrigger               (decimal value, 0-1000)     [1         ]
  SampleWindow                 (decimal value, 1-1000 sec) [10        ]
  
LOSMonitoringEnabled           (True / False)               [True     ]
  RisingTrigger                (decimal value, 1-1000)      [100      ]
  FallingTrigger               (decimal value, 0-1000)      [5        ]
  SampleWindow                 (decimal value, 1-1000 sec)  [10       ]
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.