Q-Logic 5600 Manuel D’Utilisation

Page de 336
3 – Managing Fabrics
Zoning a Fabric
59097-02 B
3-47
A
3.7.3.2
Configuring the Zoning Database
Use the Zoning Config dialog to change the Auto Save, Default Visibility, and 
Discard Inactive configuration parameters. In the faceplate display, open the 
Zoning menu and select Edit Zoning Config to open the Zoning Config dialog 
shown in 
. After making changes, click the OK button to put the new 
values into effect.
Figure 3-16.  Zoning Config Dialog
3.7.3.2.1
Interop Auto Save
The Interop Auto Save parameter determines whether changes to the active zone 
set that a switch receives from other switches in the fabric will be saved to the 
zoning database on that switch. Changes are saved when an updated zone set is 
activated. Zoning changes are always saved to temporary memory. However, if 
Interop Auto Save is enabled, the switch firmware saves changes to the active 
zone set in temporary memory and to the zoning database. If Interop Auto Save is 
disabled, changes to the active zone set are stored only in temporary memory 
which is cleared when the switch is reset.
                                                                                           
NOTE:
Disabling the Interop Auto Save parameter can be useful to prevent 
the propagation of zoning information when experimenting with 
different zoning schemes. However, leaving the Interop Auto Save 
parameter disabled can disrupt device configurations should a switch 
have to be reset. For this reason, the Interop Auto Save parameter 
should be enabled in a production environment.