Q-Logic SANBOX2-16 Manuel D’Utilisation

Page de 322
4 – Managing Switches
Displaying Switch Information
59022-11 A
4-11
0
Warning Temperature
Non-configurable temperature threshold (65° Celsius) 
above which a warning condition alarm is generated.
Failure Temperature
Non-configurable temperature threshold (70° Celsius) 
above which a failure condition alarm is generated.
NTP Client Enabled
Enabled or disabled. Allows for switches to synchronize 
their time a centralized server. 
NTP Server Address
The IP address of the centralized NTP server. Ethernet 
connection to NTP server is required. 
FDMI Enable
Fabric Device Management Interface status. If enabled, 
device information can be obtained, managed, and saved 
through the fabric using Name Service Management 
Server functions. SANsurfer Switch Manager will report 
any and all FDMI information reported by the entry switch, 
if FDMI is enabled on the entry switch. Refer to 
 for 
information about displaying FDMI information.
FDMI HBA Entry Limit
Maximum number of HBAs that can be registered with a 
switch. 
Number of Donor Groups
Total number of donor port groups. A donor group is a set 
of ports on a switch that can donate buffer credits to each 
other.
Embedded GUI
SANsurfer Switch Manager web applet status. Enables or 
disables the web applet on the switch. 
Inactivity Timeout
Number of minutes the switch waits before terminating an 
idle command line interface session. Zero (0) disables the 
time out threshold.
GUI Mgmt Enabled
Switch management application status. If disabled, the 
switch cannot be managed using the application.
Telnet Enabled
Telnet client status
SSH Enabled
Secure Shell status. If enabled, an encrypted data path is 
provided for command line interface sessions.
SSL Enabled
Secure Sockets Layer status. If enabled, encryption for 
switch management application and CIM sessions is 
provided.
Table 4-2. Switch Data Window Entries  (Continued)
Entry
Description