Isolation
Comments
1500 V
rms
Dielectric test voltage (1 minute) between coil & contacts
3.4 Twisted Pair Data Port Specifications
Data Port
Media
Distance
Connector Type
10/100 Mbps
Cat 5 UTP or STP
100m
RJ45 or M12
3.5 Fiber Optical Port Specifications
For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical
communications. The following table details fiber optic specifications based on the order code / transceiver selected at
time of ordering.
communications. The following table details fiber optic specifications based on the order code / transceiver selected at
time of ordering.
Order
Code
Mode /
Connector
Tx
λ
λ
λ
λ
(nm)
Cable
Type
Type
2
Tx Pwr
(dBm)
3
(Min/Max)
Rx
Sensitivity
(dBm)
3
Rx
Saturation
(dBm)
3
Typical
Distance
1
(km)
Power
Budget
(dB)
2LCMM
MM / LC
850
50
µ/125
-9.5 / -4
-20
0
0.5
13
2LC10
SM / LC
1310
9
µ/125
-9.5 / -3
-22
-3
10
18.5
2LC25
SM / LC
1310
9
µ/125
-5 / 0
-22
-3
25
19.5
NOTES:
1.
Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and
splices. Please consult RuggedCom sales associates when determining maximum segment distances.
2.
All cabling is duplex type unless otherwise specified.
3.
All optical power numbers are listed as dBm averages.