Basic System Configuration and Debugging 
Basic System Configuration 
Follow these steps to perform basic system configuration: 
To do… 
Use the command… 
Remarks 
Set the current date and 
time of the system 
clock datetime 
HH:MM:SS 
YYYY/MM/DD | 
MM/DD/YYYY 
Required 
Execute this command in user view. 
The default value is 23:55:00 04/01/2000 
when the system starts up.  
Set the local time zone 
clock timezone 
zone-name { add | 
minus } HH:MM:SS 
Optional 
Execute this command in user view. 
By default, it is the UTC time zone. 
Set the name and time 
range of the summer 
time 
clock summer-time 
zone_name { one-off | 
repeating } start-time 
start-date end-time 
end-date offset-time
 
Optional 
Execute this command in user view. 
When the system reaches the specified 
start time, it automatically adds the 
specified offset to the current time, so as 
to toggle the system time to the summer 
time. 
When the system reaches the specified 
end time, it automatically subtracts the 
specified offset from the current time, so 
as to toggle the summer time to normal 
system time. 
Enter system view from 
user view 
system-view 
— 
Set the system name of 
the device 
sysname sysname 
Optional  
By default, the name is device
Return from current 
view to lower level view 
quit 
Optional 
If the current view is user view, you will quit 
the current user interface. 
Return from current 
view to user view 
return 
Optional 
The composite key Ctrl+Z has the same 
effect with the return command.