3com WX3000 Manuel D’Utilisation

Page de 715
 
2-1 
2  
Monitor Link Configuration 
Introduction to Monitor Link 
Monitor Link is a collaboration scheme introduced to complement for Smart Link. It is used to monitor 
uplink and to perfect the backup function of Smart Link.  
A monitor Link consists of an uplink port and one or multiple downlink ports. When the link for the uplink 
port of a Monitor Link group fails, all the downlink ports in the Monitor Link group are forced down. When 
the link for the uplink port recovers, all the downlink ports in the group are re-enabled.  
Figure 2-1 Network diagram for a Monitor Link group implementation 
Switch A
GE1/0/1
GE 1/0/2
GE1 /0/3
Uplink
Downlink
 
 
As shown in 
, the Monitor Link group configured on the device Switch A consists of an uplink 
port (GigabitEthernet 1/0/1) and two downlink ports (GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3). 
A member port can be an Ethernet port, static LACP aggregation group, manual link aggregation group, 
or Smart Link group. A Smart Link group can serve as the uplink port only.